คำอธิบาย
Turbine มิเตอร์วัดการไหลของน้ำ แสดงอัตราการไหล ปริมาณการใช้น้ำ RS485
- PA66 nylon plus glass fiber material, light and durable
- Hall Sensor Element
- Measuring medium pure water
- Working temperature resistance 60℃
- Working pressure 1.0Mpa
- Output type NPN pulse signal
- Pulse duty cycle 50% ± 10%
- Maximum current 10mA
- Main material PA66
- Shaft material 304 stainless steel
- Electric strength AC500V 50Hz
- Insulation resistance >100MΩ
- Accumulative flow characteristic 1L = 60 Hz
- Instantaneous flow characteristic F = Q : 1
- Measuring direction bidirectional (return flow will also be measured)
- Installation direction no requirement
MOD-X4 Wiring
- 1. Red positive
- 2. Black negative
- 3. Yellow output
Output
- Output high level is 4.5V. (input voltage is 5V)
- Output high level is 23.5V. (input voltage is 24V)
Sentrol Mod X4 RS485 Modbus Water Flow Data Acquisition โมดูลการสื่อสาร
- Sentrol Mod X1 RS485 Flow Module Data Acquisition โมดูลการสื่อสาร 4 Input
- อินพุต DC5-24V
- 9600 N 8 1
- Address Defualt : 1 (address 1-255 can be changed)
- ขนาด 82x54x32mm. ไม่กันน้ำ
Modbus protocol
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 |
Default parameters: This product complies with MODBUS protocol instructions Available command codes 0x03, 0x06, 0x1 Device default parameters: Baud rate: 9600 (decimal) MODBUS device address: 1 (decimal) Flow meter constant K value: 500 (decimal) Register address and Register function 0x0000 baud rate 0x0001 device address, can be modified to 0x0001-0x00FE (decimal 1-254) 0x0002 Sensor pulse K value, the value read and written is 10 times the actual value 0x0003 Permanent accumulated flow high register, unit, L 0x0004 Permanent cumulative flow low register, unit, L 0x0005 Permanent cumulative flow decimal, the reading is 100 times the actual value, unit, L 0x0006 Permanent cumulative flow pulse value 0x0007 Temporary accumulated flow high register, unit, L 0x0008 Temporary accumulated flow low register, unit, L 0x0009 Temporary cumulative flow decimal, the reading is 100 times the actual value, unit, L 0x000A Temporary cumulative flow pulse value 0x000B Real-time flow, unit: L/min, the reading is 100 times the actual value 0x000C output point 1, control solenoid valve 1, input 0x00FF, turn on, 0x0000, turn off The baud rate defaults to 9600 and the reading is 2. If you modify the baud rate, please modify the parameters as follows. (The parameters that can be modified are 0-3. If the data input is not a value between 0-1, the baud rate is 9600, but it will be displayed as the modified value is not 0 when reading) Register parameters Baud rate 0 2400 1 4800 2 9600 3 19200 Baud rate parameter modification method: The default baud rate is 9600, and the reading is 0. If you modify the baud rate, modify the parameters as follows. (If you enter a value that is not in the table, the baud rate will be restored to 9600, but it will be displayed as the modified value is not 0 when it is read.) Precautions: 1. After the address, baud rate, K value, and permanent cumulative flow are modified, the device needs to be restarted to take effect. 2. Please close the pipeline before clearing the accumulated flow to prevent water from passing through after the clearing. After 60 seconds, the value will change. If the program changes the value again, the accumulated flow cannot be reset to zero. 3. The temporary accumulated flow will be cleared after power failure, and the permanent accumulated flow will be recorded once every 60S. (The change in flow rate must exceed 1L within 60S to be recorded) |
ข้อควรระวัง
- เพื่อป้องกันไม่ให้อนุภาคและเศษฝุ่นเข้าไปในเซนเซอร์ ต้องติดตั้งตัวกรองด้านน้ำเข้า
- หากมีแม่เหล็กหรือวัสดุที่สร้างแรงแม่เหล็กวางบนเซ็นเซอร์หรืออยู่ใกล้กับเซ็นเซอร์ จะส่งผลกระทบต่อความแม่นยำในการวัด
- การติดตั้งต้องหลีกเลี่ยงหรืออยู่ห่างสภาพแวดล้อมที่มีสั่นสะเทือน เพื่อไม่ให้ส่งผลกระทบต่อความแม่นยำในการวัด
- การถอดแยกชิ้นส่วนเซ็นเซอร์จะไม่ครอบคลุมในการรับประกัน
ในชุดประกอบด้วย
- 1 Set x มิเตอร์วัดการไหลของน้ำ Turbine Water Flow Meter RS485 5-24V DN25 YF-G1
- 1 Set x Sentrol Mod X4 RS485 Water Flow Data Acquisition โมดูลการสื่อสาร 4 Input
เซ็นเซอร์การไหลของน้ำส่วนใหญ่จะใช้ใน เครื่องทำน้ำอุ่นไฟฟ้า, เครื่องซักผ้า, ตู้น้ำหยอดเหรียญ, เครื่องควบคุมน้ำ, มาตรวัดน้ำ, อุปกรณ์บำบัดน้ำ, ระบบทำความเย็น,, เครื่องมือวัด ฯลฯ
รีวิว