คำอธิบาย
Battery Capacity Tester 60W
- Operating modes: Single mode Constant Current (CC)
- Discharge Current : 0.2 – 9.99A Step 0.1A or 0.01A
- Discharge Current maximum Error : 0.7% at 0.01A
- Maximum Capacity test error : 0.5A 2.5%, 2A 1.5%, 5A and above 1.2%
- Offline ( termination ) Voltage Range : 1 – 25 V step 1V or 0.1V
- Discharge voltage : 1 – 30 V
- Maximum voltage measurement error : 1% + – 0.02V
- it can open 9.99A 6V and 20V maximum at the only open 3.00A
- Highest battery test statistic : 999.9Ah or 9999Wh, achieve value stop testing ( first value to those who stop condition )
- Board size : 100mm x 70mm x 57mm ( Fan 12mm)
- Positioning hole : 60mm x 88mm diameter 3.2mm x 5mm
- Fan control : intelligent fan control ( variable automatic temperature )
Instructions:
- A : mode settings ( default factory for electronic load mode ) : Hold down the start-stop button ( red button ) to the tester
simultaneously energized until the key is released showing Fun * When , by rotating the knob to change the setting , - “Fun1” for electronic load mode ,
- “Fun2” battery capacity test mode. Push button start and stop at the buzzer after
entering the settings, also set - “bEon” buzzer by turning the knob to open or
- “bEoF” buzzer closes After setting press the button again to start and stop at the tester restart.
Electronic Load mode:
- Turn on the power supply 12V boot into electronic load mode , ensuring in a stopped state (“RUN” does not light, otherwise the press of the start-stop switch to turn off the load ) connected to the power supply under test to the test port input power (P + P – ) , pay attention not to take the wrong polarity !
- Set current and lower voltage knob , turn the knob to set the value of the current setting position , then press the knob to change the setting digit, digital middle two digits to the right of the indicator and digital indicator VA simultaneously determine the current set position .
- Press the start-stop switch , load began to run , “RUN” lights , power is applied to the circuit under test is set to enter the discharge current , while the upper display the actual input load voltage , when the voltage drops below the set limit voltage ” RUN ” LED flashes and short beep alarm buzzer accompanied.
- The test procedure can be modified at any current , and if you need to modify the lower voltage to stop the load can modify . Note:When in alarm state , can only transfer a small current does not increase !Tester automatic power-down feature to save enough to save the set parameters and run state, when the state again after power transmission will complete before the power failure and restore data.
Battery capacity test mode:
- The test battery should be fully charged with a special charger !
- Give the tester is powered into the battery capacity test mode, connect the battery current line to P + P- positive and negative terminals , if you use four-wire clamp test, while the four-wire interface to the positive and negative voltage test fixture is connected to V + V – port.
- Turn the knob to set the discharge current and discharge voltage ( referring to two specific methods : 2 Description ) ,
one press after setting the start and stop switch , a battery tester and a first line detection, automatic identification 2-4 line ( 2-wire line identification presentation JS-2,4 identification JS - if an error please stop the test and check the wiring ) , then enter the test , if the fault code appears , refer to later explain . The testing process will round up digital noticeable battery voltage , current , and the current discharge capacity Ah discharge energy Wh, when the discharge end ( battery voltage is below the set voltage ) , the tester displays the data stays in Ah and blink rapidly , with bee shortness buzzer alarm.
- Press the start and stop at the knob or switch to stop the alarm , you can turn the knob to view the battery discharge data, including discharge capacity Ah, Wh and discharge energy platform voltage V, start-stop button is pressed again , clear the data back to the initial setting interface before testing the next section batteries.
Additional information:
- Battery test process can adjust the discharge current , if you need to re- adjust the termination voltage , you can pause by pressing the switch at the start and stop the discharge modification ( pause discharge will return to the settings page , this time discharge data is not lost , if necessary , you can long press clears the data until the start-stop switch 0.000Ah).
- Tester automatic storage can record setting parameters , and record all parameters and status at the end of the test process and test power failure alarm status , re- transmission of all automatically restored.
Fault Protection codes :
- Err1: ultra-high capacity test the battery voltage .
- Err2: battery voltage is below the set termination voltage is not connected to the battery or the battery is reversed .
- Err3: line resistance is too large or the battery can not afford to set the discharge current.
- Err4: circuit failure .
- Err6: working power is inappropriate , use a standard 12V power supply , and the supply current is not less than 0.5A.
Overheat protection
- otP: overheating protection transient overpower protection
- Ert: temperature sensor failure or the temperature is too low
- ouP: ultra-high voltage electron-load mode reverse polarity protection, power supply voltage abnormal protection
- oPP: under ultra-high power electronic load mode instantly
รีวิว